1. With different control voltages
2. With various load currents of 10A-120A
3. The terminal adopts flip-top mode for high working efficiency
Technical Parameters
ZG3NE 
Medium power single phase AC output (rail mounted type) GRM1A.png
ZG3NE Series Rail Mounted AC Output Solid State RelayZG3NE series integrated radiator (no need to calculate additional heatdissipation volume)The 22.5mm width conforms to the industrial installation design, reducingthe cabinet installation space for rail installation or screw lifting eyeinstallation.

 

 

 

DIN Rail - Single channel AC output
Load flows: 15, 20, 30 and 35 amps Control voltage: 4-32VDC Built-in RC snubber circuit and
over-voltage protection
Zero-crossing or instantaneous
conduction output
Load voltage: 24-280VC, 48-530VAC Heavy industry SCR output IP20 safe touch enclosure LED input status indication
Model composition
Product range
ZG3NE
Load phase
1A
Load voltage
2
Rated current
15
  Control voltage
D
Guide rail module 1A: Single-phase AC
output
  • 2: 24-480VAC
  • 4: 3-32VDC
  • 5: 48-530VAC
08:08 A
15:15 A
20:20 A
25:25 A
30:30 A
35:35 A
D: 04-32VDC
B: 5-200VDC
E: 70-280VAC

 

 

 

 

Assembly Instructions
Assembly Instructions.jpg 1. Position the rail to align with the top portion of the DIN rail on the back of the SSR2. Using reasonable force, push the SSR in the direction of the arrow3. To remove, place the screwdriver on the clip and swing in the direction shownWarning: Improper method of removing the product from theDIN rail may damage the locking system

 

 

Assembly Instructions
Assembly Instructions3.jpg 1. When installing SSR, the center distance of the vertical holes can be adjusted /-1.5 mm2. For proper cooling, the SSR requires air convection (such as an indoor fan).Air convection can effectively reduce SSR heat energy generated during work.When installing multiple SSR, keep the longitudinal spacing at 80mm and the lateral spacing at least 8mm.3. If air convection cannot be provided, please reduce the load current.4. Forced cooling (such as installing indoor fans and air inlets and outlets) can significantly improve thermal performance.5. The radiator temperature should not exceed 80°С тах....WARNING: Any contact with the SSR heat sink is strictly prohibited while working.

 

Terminals
output IN
Terminals-output.jpg Terminals-in.jpg
Model: DBV5.5-14 / Material: CopperWiring range: 4-6mm²Implementation standard: GB/T14315-2008 Model: DBV1.25-10 / Material: CopperWiring range: 0.5-2mm²Implementation standard: GBT14315-2008
Terminals-Model.jpg Model: ZB6A GRMcomes with a blank marker

 

 

 

 

Derating curve   Wiring diagram
     Derating curve-1.jpg Wiring diagramWiring diagram.jpg
Attention_.jpg Attention:A well ventilated working environment can effectively imrpove the working efficiency and product life of the relay

 

 

Attention
The installation, operation, maintenance and care of electrical switches should be completed by qualified personnel. We will not bear any consequences if an accident occurs due to operational problems.SSR load-side short-circuit protection must use fast fuses or fast circuit breakers. Product damage caused by short circuits will not be covered by the warranty.It is strictly forbidden to use electric screwdrivers when wiring, as this may damage the internal structure of the relay.Warning: If the heat sink of the product is hot, be sure to let the product cool before touching it. Please follow the installation instructions. Improper operation may cause serious personal injury or permanent damage to the switch.

 

 

 

Warning
Risk of electric shock, explosion or arc flash when installing the product!Please cut off the power before using the product.Non-compliance can result in death, serious personal injury or damage to equipment.Do not allow liquids or foreign objects to enter this product.

 

 

 

Size / Material
Material.jpg The shell DIN lifting eye
PBT-GF20-V0
Flame retardant grade
cm: nickel
FV-0.jpg
Heat sink  
6063A-T6
Treatment: hard anodic matte black

 

 

 

Performance parameters
ZG3NE-1A 215D/220D/230D            
output parameter            
Working voltage(47-63HZ) 24-280         VAC
Transient 4overvoltage 800         Vpk
Maximum leakage current at off state 0.25         mAms
Minimum when disconnected 500        
Maximum load current 08 15 20 30 35 Arms
One cycle surge current 170 245 400 725 725 Apk
Conduct maximum pressure drop 1.3         Vp 
Maximum use of fusel2t 128 340 880 2520 2520 A2s
Substrate thermal resistance 0.25 0.25 0.155 0.155 0.155 ℃ W
controls parameter            
Control voltage range 4-32         VDC
Minimum off voltage 1         VDC
Maximum input current 2         mA 
Minimum conduction current 0.5         mA
Nominal input impedance Current Regulated          
Maximum conduction time 8.33         ms
Maximum break time 8.33         ms
fundamental characteristics            
work environment -20 to 80        
Storage environment -40 to 100        
Input to output insulation voltage 4000         Vrms
Bottom insulation voltage 2500         Vrms
Input to output maximum capacitance 8         pF
Guide light color           green
Product weight 310        
product packaging L14.8*W13.4*T2.7         cm

 

 

Performance parameters            
ZG3NE-1A 515D/520D/530D/535D            
output parameter            
Working voltage(47-63HZ) 48-530         VAC
Transient 4overvoltage 1600         Vpk
Maximum leakage current at off state 0.25         mAms
Minimum when disconnected 500        
Maximum load current 15 20 30 35   Arms
One cycle surge current 450 750 1050 1050   Apk
Conduct maximum pressure drop 1.3         Vp 
Maximum use of fusel2t 880 2520 5500 5500   A2s
Substrate thermal resistance 0.25 0.155 0.155 0.155   ℃ W
controls parameter            
Control voltage range 4-32         VDC
Minimum off voltage 1         VDC
Maximum input current 2         mA 
Minimum conduction current 0.8         mA
Nominal input impedance Current Regulated          
Maximum conduction time 8.33         ms
Maximum break time 8.33         ms
fundamental characteristics            
work environment -20 to 80        
Storage environment -40 to 100        
Input to output insulation voltage 4000         Vrms
Bottom insulation voltage 2500         Vrms
Input to output maximum capacitance 8         pF
Guide light color           green
Product weight 310        
product packaging L14.8*W13.4*T2.7         cm

 

WARNING
1.Warning: Use the incorrect method to remove the product from the DIN guide may damage the locking system
2. The installation, commissioning, maintenance and maintenance of electrical switches shall be completed by qualified engineers. Q&W will not bear any consequences for accidents caused by operational problems
3.Warning: Do not use an electric screwdriver when connecting cables. It may permanently damage the wiring terminals and SSR internal structure
4.SSR load end short circuit protection must use fast fuse, product damage caused by short circuit is not within the warranty scope
5. Do not allow liquids or foreign objects to enter this product
Model comparison table
Q&W Crydom Celduc Autonics Carlo Gavazzi Omron Fotek THE i-Autoc
ZG3NE-1A215D CKRD2410 - SRH1-1210-N   G3PJ-215B SSR-K10DA - KVS240D10-LM
    SRH1-1215-N   G3PE-215B    
ZG3NE-1A220D CKRD2420 SUL942440 SRH1-1220-N RJ1A23D20E G3PE-225B SSR-K20DA - KVS240D20-LM
  DR2224D20U SUL842070          
    SAL942460          
    SAM943460          
ZG3NE-1A230D CKRD2430 - SRH1-1230-N RJ1A23D30E G3PJ-225B SSR-K30DA - KVS240D30-LM
  DR2224D30U     G3PE-235B SSR-K40DA  
ZG3NE-1A520D CKRD4810 SAL961360 SRH1-1410-N RGC1A60D20KKE G3PJ-515B SSR-K10DA-H GTJ480-25A KVS480D10-LM
  CKRD4820 SAL962360 SRH1-1415-N RJ1A60D20E G3PE-515B SSR-K20DA-H GTJ600-25A KVS480D20-LM
  CKRD6010   SRH1-1420-N RJ1A60D20U       KVS600D10-LM
  CKRD6020             KVS600D20-LM
  DR2260D20U              
ZG3NE-1A535D CKRD4830 SAL963460 SRH1-1430-N RJ1A60D30E G3PJ-525B SSR-K30DA-H GTJ600-35A KVS480D30-LM
  CKRD6030 SAL965460     G3PE-525B SSR-K40DA-H GTJ600-40A-22 KVS600D30-LM
  DR2260D30U SUL765070     G3PE-535B      
  DR2260D35U SUL865070            
    SUL867070            
SSR models and parameters may change at any time. The model comparison in the above table
needs to be checked against each specification parameter to ensure its accuracy.
   

 

Online Inquiry
Submit
Email
Message
WhatsApp
Top