| EN50 Series Long Distance wide Voltage series sensor | |||
![]() | ![]() | ![]() | |
| Product model | EN50-UE2000JC | EN50-US1000JC | EN50-UT200JC |
| Type | Through beam type | Retroreflective type | DIffuse type |
| Standard sensing object | Matte white board paper 20cm×20cm | ||
| Detecting distance | 2000cm | 10-1000cm | 200cm |
| Detecting target | Φ16mm Opaque materials with minimum length of Φ16mm | Φ60mm Opaque materials with minimum length of Φ60mm | Non-transparent, translucent or transparent |
| Light | Infrared 880nm | Red light LED 660nm/ Infrared 880nm | |
| Response time | Move and reset less than 1ms | ||
| Power supply | AC36-240V ±10%50/60Hz, DC24-240V ±10% (Ripple P-P:10% below) | ||
| Sensitivity | / | Adjustable by built-in VR | |
| Control output | Relay output | Capacity:DC 30V 3A Resistive load、250VAC 3A Resistive load | |
| 10 Contact orde:NO+NC | |||
| Ambient illumination | Lamp:Less than 3000LUS. Sunlight:Less than 11000LUS. | ||
| Ambient Temperature | below zero25℃~ 55℃ without icing and condensation | ||
| Material | Housing:ABS. lens:PC. | ||
| Product Standards | GB/T14048.10-2016 | ||
| Protection | IP64(IEC) | ||
![]() | |||
| EN50 Series Long Distance DC Voltage series sensor | |||
| Product model | EN50-D1E2000JC | EN50-D1S1000JC | EN50-D1T200JC |
| Type | Through beam type | Retroreflective type | DIffuse type |
| Standard sensing object | Matte white board paper 20cm×20cm | ||
| Detecting distance | 2000cm | 10-1000cm | 200cm (100x100mm white paper) |
| Detecting target | Opaque materials with minimum length of Φ16mm | Opaque materials with minimum length of Φ60mm | Non-transparent, translucent or transparent |
| Light | Infrared 880nm | Red light LED 660nm/ Infrared 880nm | |
| Response time | 1ms Move and reset less than 1ms | ||
| Power supply | 12-24VDC(10-30VDC) Ripple P-P:10% below | ||
| Sensitivity | / | Adjustable by built-in VR | |
| Control output | Relay output | Capacity:DC 30V 3A Resistive load、250VAC 3A Resistive load | |
| 10 Contact orde:NO+NC | |||
| Ambient illumination | Lamp:Less than 3000LUS. Sunlight:Less than 11000LUS. | ||
| Ambient Temperature | below zero25℃~ 55℃ without icing and condensation | ||
| Material | Housing:ABS. lens:PC. | ||
| Product Standards | GB/T14048.10-2016 | ||
| Protection | IP64(IEC) | ||
![]() | |||
| EN50 Series Standard Distance wide Voltage series sensor | |||
| Product model | EN50-UE1000JC | EN50-US500JC | EN50-UT70JC |
| Type | Through beam type | Retroreflective type | DIffuse type |
| Standard sensing object | Matte white board paper 20cm×20cm | ||
| Detecting distance | 1000cm | 5-500cm | 70cm |
| Detecting target | Opaque materials with minimum length of Φ16mm | Opaque materials with minimum length of Φ60mm | Non-transparent, translucent or transparent |
| Light | Infrared 880nm | Red light LED 660nm/ Infrared 880nm | |
| Response time | Move and reset less than 1ms | ||
| Power supply | AC36-240V ±10%50/60Hz, DC24-240V ±10% (Ripple P-P:10% below) | ||
| Sensitivity | / | Adjustable by built-in VR | |
| Control output | Relay output | Capacity:DC 30V 3A Resistive load、250VAC 3A Resistive load | |
| 10 Contact orde:NO+NC | |||
| Ambient illumination | Lamp:Less than 3000LUS. Sunlight:Less than 11000LUS. | ||
| Ambient Temperature | below zero25℃~ 55℃ without icing and condensation | ||
| Material | Housing:ABS. lens:PC. | ||
| Product Standards | GB/T14048.10-2016 | ||
| Protection | IP64(IEC) | ||
![]() | |||
| EN50 Series Standard Distance DC Voltage series sensor | |||
| Product model | EN50-D1E1000JC | EN50-D1S500JC | EN50-D1T70JC |
| Type | Through beam type | Retroreflective type | DIffuse type |
| Standard sensing object | Matte white board paper 20cm×20cm | ||
| Detecting distance | 1000cm | 5-500cm | 70cm |
| Detecting target | Opaque materials with minimum length of Φ16mm | Opaque materials with minimum length of Φ60mm | Non-transparent, translucent or transparent |
| Light | Infrared 880nm | Red light LED 660nm/ Infrared 880nm | |
| Response time | Move and reset less than 1ms | ||
| Power supply | 12-24VDC(10-30VDC) Ripple P-P:10% below | ||
| Sensitivity | / | Adjustable by built-in VR | |
| Control output | Relay output | Capacity:DC 30V 3A Resistive load、250VAC 3A Resistive load | |
| 10 Contact orde:NO+NC | |||
| Ambient illumination | Lamp:Less than 3000LUS. Sunlight:Less than 11000LUS. | ||
| Ambient Temperature | below zero25℃~ 55℃ without icing and condensation | ||
| Material | PC; Housing:ABS. lens:PC. | ||
| Product Standards | GB/T14048.10-2016 | ||
| Protection | IP64(IEC) | ||
![]() | |||